LUXR panels are 40" × 12", 26-gauge steel, packed 15 to a box for 50 sq ft of coverage, and backed by a Sherwin-Williams 40-year limited warranty.

Length × width
40" × 12"
Material
26-gauge steel
Finish
Textured, low-glare
Packaging
15 panels per box
Coverage
50 sq ft per box
Fastening
4 screws per panel minimum, 7 recommended
Ridge / hip cap
12" × 12", 12" coverage, 10 per box

Panel Specifications

SKUs

Color
Panel SKU
Ridge / hip cap SKU
Textured Matte Black
LUTMB
LURCTMB
Textured Charcoal
LUTCH
LURCTCH
Textured Burnished Slate
LUTBS
LURCTBS

SKUs

Color
Panel SKU
Ridge / hip cap SKU
Textured Matte Black
LUTMB
LURCTMB
Textured Charcoal
LUTCH
LURCTCH
Textured Burnished Slate
LUTBS
LURCTBS
Length × width
40" × 12"
Material
26-gauge steel
Finish
Textured, low-glare
Packaging
15 panels per box
Coverage
50 sq ft per box
Fastening
4 screws per panel minimum, 7 recommended
Ridge / hip cap
12" × 12", 12" coverage, 10 per box

Panel Specifications

SKUs

Color
Panel SKU
Ridge / hip cap SKU
Textured Matte Black
LUTMB
LURCTMB
Textured Charcoal
LUTCH
LURCTCH
Textured Burnished Slate
LUTBS
LURCTBS
Length × width
40" × 12"
Material
26-gauge steel
Finish
Textured, low-glare
Packaging
15 panels per box
Coverage
50 sq ft per box
Fastening
4 screws per panel minimum, 7 recommended
Ridge / hip cap
12" × 12", 12" coverage, 10 per box

Panel Specifications

System Components

Use only LUXR-approved trim and flashing. Non-approved accessories void warranty coverage.

drip-edge.png

Locks the first course at the eave.

Drip Edge

rake.png

Anchors panel ends at the gable.

Rake

sidewall.png

Vertical flashing at walls.

Sidewall

apron.png

Front-of-penetration flashing.

2-pc Endwall

valley.png

Double-J ice and water protection.

Valley

cleat-offset.png

Locks panels without a drip edge.

Cleat Offset

Test
Status
Fire
Class A assembly with a code-specified fire-rated underlayment
Cool roof rating
To be filed with the Cool Roof Rating Council on completion
Regional approvals
High-wind / hurricane-zone approvals pending where applicable
Corrosion resistance
Third-party testing in progress
Impact resistance
Third-party testing in progress
Wind uplift
Third-party testing in progress

Testing & Certification

LUXR is in third-party testing. Final ratings, agency reference numbers and fastener-to-wind-rating schedules will be published here and in the LUXR Installation Manual v2.

Test
Status
Fire
Class A assembly with a code-specified fire-rated underlayment
Cool roof rating
To be filed with the Cool Roof Rating Council on completion
Regional approvals
High-wind / hurricane-zone approvals pending where applicable
Corrosion resistance
Third-party testing in progress
Impact resistance
Third-party testing in progress
Wind uplift
Third-party testing in progress

Testing & Certification

LUXR is in third-party testing. Final ratings, agency reference numbers and fastener-to-wind-rating schedules will be published here and in the LUXR Installation Manual v2.

Test
Status
Fire
Class A assembly with a code-specified fire-rated underlayment
Cool roof rating
To be filed with the Cool Roof Rating Council on completion
Regional approvals
High-wind / hurricane-zone approvals pending where applicable
Corrosion resistance
Third-party testing in progress
Impact resistance
Third-party testing in progress
Wind uplift
Third-party testing in progress

Testing & Certification

LUXR is in third-party testing. Final ratings, agency reference numbers and fastener-to-wind-rating schedules will be published here and in the LUXR Installation Manual v2.

Warranty

40-year limited warranty.

LUXR Metal Shingles are backed by a published Sherwin-Williams 40-year limited warranty.

​

What can void it

  • Non-LUXR-approved trim, flashing or accessories

  • Copper, aluminum or lead accessories in contact with the panels

  • Pressure washers, wire brushes, scouring pads or harsh solvents